FRIALIT-DEGUSSIT Technical Ceramics

 

HomeNewsAbout UsMaterialsTubes, Rods & LabwareCeramic-metal SealsDesign NotesStandard DesignsEngineering CeramicsFine Grinding ToolsApplication AreasDownloadsContacts

Ceramic-metal Seals

 

Standard Designs

Single Terminal Feedthroughs

Multi-Terminal Feedthroughs

Tube Insulators

Stand-offs

 

SINGLE TERMINAL FEEDTHROUGHS

Voltage (DC)

M

D

F

J

G

K

L

L1

Article no.

4 kV

M4

1,6

7,0

3,0

8

15

41

10

551-1001

6 kV

M6

2,5

9,0

4,0

13

20

47

10

551-1002

6 kV

M6

2,5

10,8

5,0

13

20

47

10

551-1003

6 kV

M8

3,8

13,5

6,5

13

20

54

17

551-1004

This is by no means an exhaustive list - these designs are shown as examples of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   

Voltage
(DC)

Conductor

Current

D

F

G

K

L1

L2

L

Article no.

1 kV

Ni42

5 A

1,5

10,8

4

22

12

 

75

551-0725

2 kV

NiFeCo

4 A

1,5x0,25

5

4

10,5

10

7

60

551-1063

2 kV

NiFeCo

5 A

1,5x0,25

5

4

10,5

10

7

60

551-1064

3 kV

NiFeCo

5 A

1,5x0,25

5

6

12,5

10

7

60

551-1066

3 kV

Cu

15 A

1,5x0,25

5

6

12,5

10

7

60

551-1066-2

4 kV

Ni42

5 A

1,5

7

8

15

10

13

57

551-0412

4 kV

Cu

15 A

1,5

7

8

15

10

13

57

551-0412-1

4 kV

Ni42

8 A

2,0

7

8

15

10

13

57

551-1006

4 kV

Cu

25 A

2,0

7

8

15

10

13

57

551-1006-1

5 kV

NiFeCo

5 A

1,5x0,25

5

10

16,5

10

7

60

551-1068

5 kV

Cu

15 A

1,5x0,25

5

10

16,5

10

7

60

551-1068-2

6 kV

Ni42

12 A

3,0

9

13

20

10

13

58

551-1007

6 kV

Cu

40 A

3,0

9

13

20

10

13

58

551-1007-1

6 kV

Ni42

20 A

4,0

10,8

13

20

10

13

58

551-1008

6 kV

Cu

60 A

4,0

10,8

13

20

10

13

58

551-1008-1

6 kV

Ni42

25 A

5,0

13,5

13

20

10

13

65

551-1009

6 kV

Cu

80 A

5,0

13,5

13

20

10

13

65

551-1009-1

8 kV

Cu

120 A

8,0

19,8

16

23

10

13

68

551-1010-1

This is by no means an exhaustive list - these designs are shown as examples of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   

Voltage
 (DC)

Conductor

Current

D

F

G

K

L1

L2

L

Article no.

1 kV

Ni42

4 A

1,5 x 0,25

4

2,8

4,4

6

10

35

551-1491

1 kV

Ni42

5 A

1,5

4

2,8

4,4

6

10

35

551-1425

1 kV

Cu

5 A

1,5

4

2,8

4,4

6

10

35

551-1425-1

4 kV

Ni42

30 A

7,5 x 0,75

12

8

13

10

14

53

551-1633

4 kV

Cu

90 A

7,5 x 0,75

12

8

13

10

14

53

551-1633-1

This is by no means an exhaustive list - these designs are shown as examples of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   

Voltage
(DC)

No. of
Flutes

Leakage
Path

M

D

F

A

A1

G

K

K1

L2

Article
no.

25 kV

3

54

M6

2,5

45

40

22

45

66

12

67

551-1012

This is by no means an exhaustive list - this design is shown as an example of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   

Voltage
(DC)

No. of
Flutes

Leakage
Path

M

D

F

A

A1

G

K

K1

L2

Article
no.

50 kV

8

150

M8

3,8

88,9

70

52

108

-

31,6

141,4

551-0970

This is by no means an exhaustive list - this design is shown as an example of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

Back to top

Multi-Terminal Feedthroughs

Voltage
(DC)

Current

D

J

F

G

L1

L2

L

Article no.

500 V Pin-Pin
1 kV Pin-Flange
 

4 A

1,5 x 0,25

5

10,8

5

10

17

32

552-0861
(2-terminal)

500 V Pin-Pin
1 kV Pin-Flange
 

4 A

1,5 x 0,25

5

10,8

5

10

17

32

552-0838
(4-terminal)

This is by no means an exhaustive list - these designs are shown as examples of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   

Voltage (DC)

Current

D

A

G

J

L1

L2

L

Article no.

500 V Pin-Pin
1 kV Pin-Flange

4 A

1,5 x 0,225

7

13,2

15,7

5

9

27

552-2548
(5-terminal)

This is by no means an exhaustive list - this design is shown as an example of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

 Back to top

Tube Insulators

Voltage
(DC)

No. of
Flutes

Leakage
Path

Available
with

F

A

J

G

L

Article
no.

15 kV

3

44

35

36

46

25

30

67,6

559-0654

This is by no means an exhaustive list - this design is shown as an example of the type of construction which is possible, from the hundreds of designs which we produce - many to custom requirements.  The design can be changed and/or special fittings or conductors added for individual situations

   
 
   
 

Back to top

Stand-offs

 
   
 
   
 

Back to top

 

Send mail to webmaster@degussit.com with questions or comments about this web site.
Copyright 2008-2013 FRIALIT-DEGUSSIT Technical Ceramics
Last modified:
Tuesday, 08 January 2013